◇ Introduction ◇ Function◇ Parameter◇ Product order◇ Download◇ Related products
Introduction
DT Pro Wireless Temperature / Humidity / Pressure Calibration System can be widely used in equipment calibration and environmental monitoring in pharmaceutical, food, biological, chemical and other industries. Wireless calibration system Compared with the traditional wired calibration system, the probe can be conveniently and quickly arranged, and the detection point is physical constraints greatly improve calibration efficiency.
Function
The system consists of a wireless recorder (temperature, humidity, pressure), a data reading workstation, and wireless calibration software.
DT Pro temperature calibration system can effectively store 16000 pieces of data, and the temperature measurement accuracy is 0.1 ℃, which fully meets the needs of equipment and process calibration in food and drug production enterprises and the calibration needs in the fields of bioengineering, medical and transportation. The recorder uses replaceable batteries, with large power, low power consumption and long battery life. Adopt high pressure and waterproof design, can be used continuously for a long time in high pressure and high humidity environment.
The data reading workstation is divided into a single-hole workstation and a 10-hole workstation. The universal USB serial port is used to connect to the computer, and data communication can be carried out conveniently, efficiently and safely.
The software realizes data collection, data analysis and report generation, meets FDA 21 CFR Part 11, and supports electronic signature of documents. Support custom stages and verify each stage to generate stage calibration report.
Features:
◇ Switch between Chinese and English versions at will;
◇ Comply with FDA 21CFRPart 11 regulations;
◇ With data audit tracking function, with three levels of authority (freely assignable authority);
◇ It has data statistical analysis functions, including large and small values, average value, span, temperature difference at the same time, F0 value test, etc., and can be freely selected according to needs.
Application scenarios:
DT Pro Pressure / Temperature / Humidity Calibration System can be applied to GMP pharmaceutical industry, GSP industry, biological industry, medical industry, food industry, transportation industry.
GMP | Steam sterilizer calibration / water bath sterilizer verification, rubber plug washer calibration / aluminum lid washer verification, freeze dryer calibration / cryogenic refrigerator verification, constant temperature and humidity chamber calibration / stability incubator calibration |
GSP | Cold storage verification / refrigerated truck calibration, refrigerator / incubator verification, cool storage / normal temperature storage calibration |
Biological | Stirred fermentation tank verification, culture bath calibration, process development data |
Food | Pasteurization verification, sterilization tunnel calibration, rotary freezer verification, blast freezer calibration, cold room calibration |
Transport | Cold chain process tracking, cabin temperature detection |
Medical | High temperature sterilization testing, steam sterilization testing, medical supplies testing |
Implemented procedures and specifications:
Serial number | Regulation code | Procedure name |
1 | GBT 30690-2014 | The sterilization effect monitoring method and evaluation requirements of small pressure steam sterilizer |
2 | PDA TR1-2007 | Damp heat sterilization verification |
3 | JJF 1366-2012 | "Calibration Regulations for Temperature Data Collector" |
4 | JJF 1101-2003 | "Code for Calibration of Temperature and Humidity of Environmental Test Equipment" |
Related regulations | "Pharmaceutical Production Quality Management Standards" (revised in 2015) "Guidelines for Pharmaceutical Production calibration" (2003 edition) FDA 21CFRPart11 Clause EN285-2006 (German Standard) EN554: 1994 (German Standard) HTM2010 (British Standard) |
Technical Parameters
Temperature Calibrator | Temperature and humidity calibrator | Pressure Calibrator | ||
Model | TDLA | TDLC(Flexible probe) | MDLA | PDLA |
Operating temperature | -50 ~ 150 ° C (expandable to 400˚C with heat insulation box) | -50 ~ 150 ° C (expandable to 400˚C with heat insulation box) | -40~125°C | -40~140°C |
Range | -50~150°C | -50~150°C | 0~100%RH | 0~100psi 0~6.894Bar (Absolute pressure) |
Resolution | 0.01°C | 0.01°C | 0.01°C | 0.008psi; |
0.01%RH | 0.55mBar | |||
Accuracy | ±0.1°C | ±0.1°C | ±0.2°C | ±2.5% Full scale |
±2%RH | ||||
Sensor | Pt100 Class 1/3 DIN | Pt100 Class 1/3 DIN | Temperature: Pt100 | Strain |
Humidity: capacitive | ||||
Capacity (recording points) | 64,000 | 64,000 | 8,000 | 8,000 |
Record frequency | 1 second to 18 hours | 1 second to 18 hours | 1 second to 18 hours | 1 second to 18 hours |
Battery Life | 36 months | 36 months | 12 months | 12 months |
Communication method | RS 485 Contact | RS 485 Contact | RS 485 Contact | RS 485 Contact |
Previous:DTWX-01G Wireless Temperature Humidity Acquisition/Inspection System | next:Custom temperature and humidity verification/calibration chamber |